Coating Inspection
Inspection of protective coating application and surface preparation on industrial assets.
Specialist Coating Inspection Services
Independent coating inspection, testing and quality assurance for structural steel, storage tanks, bridges and industrial assets across the UK and Europe.
Discuss Your ProjectOur coating inspection division is comprised of a team of Senior Coating Inspectors (BGAS Level II, ICorr Level II, NACE Level II and FROSIO Level III) with extensive experience in the coating of structural steel on bridges, offices and highways, and also petrochemical storage tanks at Navigator Terminals and break-water tanks for Southern Water.
Helping to conduct our work, we use top-of-the-line coating instruments (DFT gauge, surface profile gauge, humidity check, adhesion tester, etc.) calibrated annually.
“Improving Quality, Reducing Costs”
Independent inspection, testing, reporting and quality assurance support for protective coatings.
Inspection of protective coating application and surface preparation on industrial assets.
Film thickness, surface profile, humidity and adhesion checks using calibrated instruments.
Inspection documentation, findings and practical technical recommendations.
Cost and resource estimation support for coating inspection work.
Project Quality Plans (PQP), Inspection and Test Plans (ITP) and paint procedures.
Quality audits and review of coating-related supplier and vendor documentation.
Daily logs, punch lists, preliminary surveys, applicator reports, accreditation checks and calibration certificates.
PosiTector UT/DFT instruments for film thickness measurements on suitable substrates, alongside surface preparation checks.
Inspection and test planning with reference to NORSOK M-501 (2022) and ISO 12944, as specified for the project.
Examples of coating inspection, testing and remedial work.
London, UK
A nine-month intumescent (passive fire protection) coating project at an 11,500 m² office building across nine floors.
The work required careful inspection to ensure at least 60 minutes of fire resistance. Application and testing followed a framework informed by the Association for Specialist Fire Protection TGD (2014), as described in the project brief.

United Kingdom
Mechanical surface abrasion, cleanliness checks, joint sealing and application of a 1,000 µm solvent-free Acothane coating.
Tank hygiene requirements included new PPE and DWI-approved materials. The team applied bond-breaker tape and GRP strips, then recorded film thickness with an ultrasonic gauge and WFT readings per panel.

Cornwall, UK
Patch repairs, jet washing and a cosmetic coat following premature coating degradation in a harsh coastal environment.
Previous coating work had film-thickness non-conformances in some areas. The coastal conditions exacerbated degradation and prompted remedial inspection and repair.

United Kingdom
Surface preparation and corrosion protection of a partially underground methane (biogas) pipe and flange.
The surface received deionised water treatment and salt testing, power brushing to St 3 under GIS PA10 (2022), Jotamastic 87 and two Hardtop Flexi coats. Nominal system thickness: 325 µm.

Our inspection work is supported by annually calibrated instruments, including dry film thickness gauges, surface profile gauges, humidity checks and adhesion testing equipment.
Inspection planning can reference NORSOK M-501 (2022) and ISO 12944, in line with the relevant project specifications.


From condition surveys and specification reviews to independent inspection, testing and failure investigation, speak directly to our technical team.
Discuss Your ProjectChoose a number to discuss your coating inspection project.