Specialist Coating Inspection Services

Coating Inspection for Critical Assets

Independent coating inspection, testing and quality assurance for structural steel, storage tanks, bridges and industrial assets across the UK and Europe.

Discuss Your Project
Incorporated
in 2018
UK & Europe
Wide Coverage
BGAS, NACE, ICorr & FROSIO
Qualified Inspectors
Independent
Third-Party Inspection

Who We Are

Our coating inspection division is comprised of a team of Senior Coating Inspectors (BGAS Level II, ICorr Level II, NACE Level II and FROSIO Level III) with extensive experience in the coating of structural steel on bridges, offices and highways, and also petrochemical storage tanks at Navigator Terminals and break-water tanks for Southern Water.

Helping to conduct our work, we use top-of-the-line coating instruments (DFT gauge, surface profile gauge, humidity check, adhesion tester, etc.) calibrated annually.

“Improving Quality, Reducing Costs”

PosiTector gauge used during coating inspection and quality control

Our Services

Independent inspection, testing, reporting and quality assurance support for protective coatings.

Coating Inspection

Inspection of protective coating application and surface preparation on industrial assets.

QA/QC Testing

Film thickness, surface profile, humidity and adhesion checks using calibrated instruments.

Reporting & Recommendations

Inspection documentation, findings and practical technical recommendations.

Coating Inspection Cost Estimation (CTR)

Cost and resource estimation support for coating inspection work.

QA Documentation

Project Quality Plans (PQP), Inspection and Test Plans (ITP) and paint procedures.

Supplier & Vendor Auditing

Quality audits and review of coating-related supplier and vendor documentation.

How We Protect Your Assets

Documentation Control

Daily logs, punch lists, preliminary surveys, applicator reports, accreditation checks and calibration certificates.

QA/QC Testing

PosiTector UT/DFT instruments for film thickness measurements on suitable substrates, alongside surface preparation checks.

Inspection & Test Plans

Inspection and test planning with reference to NORSOK M-501 (2022) and ISO 12944, as specified for the project.

Our Projects

Examples of coating inspection, testing and remedial work.

Intumescent fire protection coating on structural steel at Finsbury Square London

Intumescent Coating of Finsbury Square

London, UK

A nine-month intumescent (passive fire protection) coating project at an 11,500 m² office building across nine floors.

View Project

The work required careful inspection to ensure at least 60 minutes of fire resistance. Application and testing followed a framework informed by the Association for Specialist Fire Protection TGD (2014), as described in the project brief.

Coating inspector working on site at Finsbury Square
GRP water storage tank inspection and protective coating work

GRP Water Storage Tank

United Kingdom

Mechanical surface abrasion, cleanliness checks, joint sealing and application of a 1,000 µm solvent-free Acothane coating.

View Project

Tank hygiene requirements included new PPE and DWI-approved materials. The team applied bond-breaker tape and GRP strips, then recorded film thickness with an ultrasonic gauge and WFT readings per panel.

Inspection instrument used to verify protective coating measurements
Tintagel Bridge in Cornwall photographed in daylight

Coating Remedial Works of Tintagel Bridge

Cornwall, UK

Patch repairs, jet washing and a cosmetic coat following premature coating degradation in a harsh coastal environment.

View Project

Previous coating work had film-thickness non-conformances in some areas. The coastal conditions exacerbated degradation and prompted remedial inspection and repair.

Tintagel Bridge remedial coating works photographed at night
Protective coating applied to a partially underground yellow biogas pipe and valve

Valves, Flanges & Underground Pipes

United Kingdom

Surface preparation and corrosion protection of a partially underground methane (biogas) pipe and flange.

View Project

The surface received deionised water treatment and salt testing, power brushing to St 3 under GIS PA10 (2022), Jotamastic 87 and two Hardtop Flexi coats. Nominal system thickness: 325 µm.

Close-up of a coated industrial pipe flange

Inspection Equipment & Standards

Our inspection work is supported by annually calibrated instruments, including dry film thickness gauges, surface profile gauges, humidity checks and adhesion testing equipment.

Inspection planning can reference NORSOK M-501 (2022) and ISO 12944, in line with the relevant project specifications.

DFT / UTSurface ProfileHumidityAdhesionISO 12944NORSOK M-501
Analogue coating thickness gauge used by an inspectorPosiTector coating inspection measuring instrument

Have a Coating Problem?
Talk to One of Our Inspectors.

From condition surveys and specification reviews to independent inspection, testing and failure investigation, speak directly to our technical team.

Discuss Your Project